The definitive guide to balance operation :Avoiding risks with Scientific solutions

Daicy 2025-04-30 22:40:18

Electronic balances, as precision instruments, are often subject to overlooked errors that can compromise measurement accuracy or damage the device. Below are common yet neglected mistakes and key precautions:


I. Operational Procedure Errors

  1. Skipping Warm-up
    Balances require sufficient warm-up time to reach thermal equilibrium. Immediate use without preheating may cause zero drift or unstable readings1.
  2. Ignoring Leveling Before Use
    An unleveled balance unevenly distributes load on the sensor, introducing errors. Some models require manual adjustment of the leveling bubble to the center.
  3. Weighing Hot/Cold Samples Directly
    High- or low-temperature samples create air currents or thermal effects, skewing results.

II. Calibration and Parameter Setting Errors

  1. Using Non-standard Weights for Calibration
    Substituting standard weights with improper objects (e.g., underweight items) may trigger overload errors (e.g., "H" error). Always use certified calibration weights and follow protocols.
  2. Confusing Scale Interval (e) and Verification Scale Interval (d)
    The scale interval (e) determines error evaluation and precision. Mistaking d for e when selecting a balance may render it unsuitable for intended accuracy5.

III. Measurement Execution Errors

  1. Reading Values Prematurely
    Wait for the displayed value to stabilize before recording; early readings introduce inaccuracies.
  2. Handling Powders/Corrosive Samples Barehanded
    Direct contact with gloves or tools may contaminate or corrode the balance. Use protective tools or weighing paper.
  3. Overloading the Balance
    Exceeding the maximum capacity damages the sensor. Always verify sample weight limits beforehan.

IV. Environmental and Maintenance Oversights

  1. Neglecting Airflow and Vibration
    Placing the balance near vents, fans, or vibrating surfaces, or allowing the draft shield to contact the pan, may cause errors (e.g., "L" error).
  2. Failing to Clean Residual Debris
    Accumulated samples or liquids under the pan reduce sensor sensitivity. Clean regularly.
  3. Using Metal Tools for Corrosive Substances
    Metal tweezers risk scratching the pan. Opt for anti-static plastic tools or weighing paper.

V. Special Scenario Errors

  1. Frequent Power Cycling
    Repeatedly turning the balance on/off accelerates component aging. Keep it powered during continuous use.
  2. Mismatched Balance Selection
    For volatile/corrosive substances (e.g., acids), use corrosion-resistant models instead of standard analytical balances
logo

Electronic balance/Weighing Indicator/Jewelry scale

Contact us

Shenzhen Big Dipper Scale Co.,Ltd,No. 88, Tengchang 1st Road, Silian Community,Henggang Sub-district,Longgang District Shenzhen, China

86 0755-28644346

8613544043334

bdscales02@weiaite.com

logo

Electronic balance/Weighing Indicator/Jewelry scale

Contact us